      安科瑞DJSF1352-RN直流電表在俄羅斯UPS電能計量系統中的應用

      發布日期:2022-05-18 點擊率:73

      安科瑞 師晴晴

      江蘇安科瑞電器制造有限公司 江蘇江陰

      摘要:本文介紹了安科瑞DJSF1352-RN直流電表在俄羅斯UPS計量系統中的應用。主要用于UPS系統中的輸出電能的計量,通過霍爾對電路系統進行計量、通訊和控制等。

      Abstract: This article introduces the application of “Acrel” DJSF1352-RN DC meter in the Russian UPS metering system. It is mainly used for the measurement of the output energy in the UPS system, and the measurement, communication and control of the circuit system through the Hall sensor.

      1.項目概述:Project Overview

      該公司位于俄羅斯是一家電池生產公司。主要在俄羅斯從事工業電池及UPS的生產和供應。客戶要使用直流電表,用于UPS輸出端電能的監測計量。

      The company is located in Russia and is a battery production company. Mainly engaged in the production and supply of industrial batteries and UPS in Russia. The customer needs to use a DC meter for monitoring and measuring the electrical energy at the output of the UPS.

      2.DJSF1352-RN介紹 DJSF1352-RN DC Energy Meters

      DJSF1352-RN導軌式直流電能表,主要針對電信基站、直流充電樁、太陽能光伏等應用場合而設計,該系列儀表可測量直流系統中的電壓、電流、功率以及正反向電能等。在實際使用現場,即可計量總電能,又可計量規定時間段內的電能。檢測的結果既可用于本地顯示,又能與工控設備、計算機連接,組成測控系統。

      儀表可具有紅外通訊接口和RS-485通訊接口,同時支持Modbus-RTU協議和DLT645-97(07)協議;可帶繼電器警報輸出和開關量輸入功能;根據不同要求,通過儀表面板按鍵,對變比、警報、通訊進行設置;具有開關量事件記錄(Modbus協議)、編程和事件設置記錄(645協議)、數據瞬時和定時凍結功能(645協議)、電壓電流功率峰值、谷值記錄功能。

      DJSF1352-RN rail-mounted DC power meter designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system.The actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.

      The meter can have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.The meter can have relay alarm output and digital input function;You can set the ratio, alarm, and communication through the meter panel keys according to different requirements.The meter can have event recording of switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), maximum and minimum value recording function of voltage and current power.

       

      3.型號及功能介紹 Type and Function Description

       

       

      Notewhen dual DC inputDfunction is selectedif Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided, the built-in power supply of electric meter can be used.

      Technical parameters

      Index

      Input

      Nominal value

      Voltage input range

      Current input

      DC 0-1000V

      Hall sensor0-20mA4-20mA0-5V0-10V and so on.

      Overload

      1.2 times rated (continuous); 2 times rated/1 second;

      Power consumption

      Voltage: ≤0.2VA, current ≤0.1VA

      Accuracy class

      Class 1

      Function

      Display

      8-bit segment LCD screen (LCD)

      Communication Interface

      RS485two options

      Communication protocol

      Modbus-RTUDL/T 645-2007

      Switch

      Switch output

      2 Relay outputs, 2A/30VDC or 2A/250VAC

      Switch input

      2 dry contact inputs

      Pulse output

      A second pulse output, a energy pulse output

      See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWh

      Power Supply

      Voltage range

      AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)

      Power consumption

      ≤ 3W

      Power frequency withstand voltage

      Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min

      Power supply // Relay output // Voltage input // Current input 3kV/1min

      Pulse output // Communication interface // Switch input 2kV/1min

      Impulse withstand voltage

      ±6KV

      Insulation resistance

      ≥ 40M ?

      Average barrier-free working hours

      ≥50000h

      Environment

      Temperature

      Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C;

      Storage temperature: -40+80

      Humidity

      ≤93%RH, no condensation, no corrosive gas

      Altitude

      ≤2500m

       

      4.客戶要求 Customer Requirements

      客戶想計量UPS的實際輸出電能,來計算UPS儲能與耗能的轉化比,UPS輸入端用的是我們ADL系列的電表,輸出端用的是DJSF1352-RN直流電表,通過分流器采取電信號,達到輸出端測量的目的。

      The customer wants to measure the actual output power of the UPS to calculate the conversion ratio of UPS energy storage to energy consumption. The UPS input end uses our ADL series electric meter, the output end uses DJSF1352-RN DC meter, and the electrical signal is taken through the shunt in order to achieve the purpose of output measurement.

      參考文獻 Bibliography

      1.Solutions For Enterprise Micro-grid System 2021.04


      下一篇: PLC、DCS、FCS三大控

      上一篇: 100公斤手握式S型數顯

      推薦產品

      更多
      主站蜘蛛池模板: 久久九九精品国产综合喷水| 国产成人综合在线视频| 九色综合狠狠综合久久| 色综合一区二区三区| 一本色道久久综合狠狠躁篇| 91精品国产91久久综合| 亚洲综合久久1区2区3区| 狠狠色狠狠色很很综合很久久| 狠狠色丁香婷婷综合久久来来去| 狠狠色色综合网站| 国产成人综合久久精品红| 久久精品综合一区二区三区| 色综合色综合久久综合频道| 六月婷婷激情综合| 亚洲综合区图片小说区| 激情综合色综合啪啪开心| 伊人色综合网一区二区三区| 狠狠综合久久AV一区二区三区| 天天综合天天综合| 色综合a怡红院怡红院首页| 国产精品无码久久综合| 五月丁香六月综合缴清无码| 激情综合亚洲色婷婷五月APP| 国产综合色在线精品| 日日狠狠久久偷偷色综合0| 狠狠色丁香久久婷婷综合蜜芽五月 | 久久婷婷香蕉热狠狠综合| 国产香蕉尹人综合在线观看| 曰韩人妻无码一区二区三区综合部| 亚洲色欲色欲综合网站| 亚洲香蕉网久久综合影视| 狠狠人妻久久久久久综合| 成人综合伊人五月婷久久| 亚洲综合区小说区激情区| 亚洲国产精品综合久久网络 | 狠狠色丁香九九婷婷综合五月| 色婷婷综合久久久中文字幕| 情人伊人久久综合亚洲| 久久香蕉综合色一综合色88| 91精品国产色综合久久不卡蜜| 伊人久久大香线焦综合四虎|